Skip to main content
Home » Resources » Gas Supply Guides » Welding gas chart
regulators

Welding gas chart: the right gas for the metal, by thickness

MIG, TIG, flux-core — a working trade chart. Pin it next to the welder.
Last reviewed: 18 April 2026
This is the chart a trade shop actually wants printed next to the welder. Pick the gas for the metal first, the thickness second, and the process third — then size the cylinder to your draw rate.

The trade default, in one line

For mild-steel MIG work, an argon/CO₂ 82/18 or 80/20 mix is the working default. Clean bead, manageable spatter, fair cost per cubic metre. If a workshop only runs one cylinder, that’s the one.

For TIG on anything, use pure argon (welding-grade 99.997%, or 5.0 where precision matters). That covers most of the work most shops do.

Everything below shows what to change when the default isn’t right.

Mild steel — MIG

ThicknessShielding gasPurityTypical flowNotes
≤1.6mmAr/CO₂ 82/1899.997%12–15 L/minThin section, prone to burn-through. Keep travel speed up.
1.6–3mmAr/CO₂ 82/1899.997%13–16 L/minSweet spot for the default mix.
3–6mmAr/CO₂ 80/2099.997%15–18 L/minSlightly hotter arc. Can also use 82/18 at higher amps.
6–10mmAr/CO₂ 75/2599.997%17–20 L/minDeeper penetration. Multi-pass likely.
>10mmPure CO₂ or Ar/CO₂ 75/2599.5% / 99.997%18–22 L/minPure CO₂ wins on penetration; trade clean bead for fusion.

Pure CO₂ is cheap and runs hot. Fine for structural and hidden welds; less ideal where finish matters.

Mild steel — flux-core (FCAW)

Two flavours, different rules:

  • Self-shielded (FCAW-S) — no gas. The flux does the whole job. Good for windy sites.
  • Gas-shielded (FCAW-G) — run 100% CO₂ or Ar/CO₂ 75/25. Higher deposition than solid-wire MIG, useful on heavy structural.

Stainless steel — MIG

Pure argon doesn’t work for stainless MIG — the arc is cold and unstable. You need a small active component to stabilise it.

ThicknessShielding gasNotes
≤3mmTri-mix (Ar 90 / He 7.5 / CO₂ 2.5)Best bead profile, low carbon pickup.
≤3mm budgetAr/O₂ 98/2Cheaper. Slightly harsher arc. Fine for non-cosmetic work.
3–6mmTri-mixHotter arc from helium helps on thicker sections.
>6mmTri-mix or Ar/O₂/CO₂ custom blendCall for a mix matched to your wire — we’ll size it.

Stainless steel — TIG

Pure argon 5.0 (99.999%). Add a backing gas (also pure argon) for full-pen root passes on pipe — contamination of the back side will ruin the weld.

Aluminium

Process dictates the gas here:
Process Thickness Gas Notes
MIG ≤6mm Pure argon Welding grade 99.997% is fine.
MIG 6–12mm Ar/He 75/25 Helium adds heat, speeds travel.
MIG >12mm Ar/He 50/50 Preheat may still be needed.
TIG Any Pure argon 5.0 Period. Never compromise.
Oxygen in the stream oxidises aluminium at the edge and gives you a dirty weld. Never run a CO₂ mix on aluminium.

Reactive metals (titanium, zirconium)

Argon 5.0 at minimum, and purge the back side. Consider a purge chamber for critical welds. These metals will react with any residual atmosphere at welding temperature.

Flow-rate and draft rules of thumb

  • Indoor still air — around 12–18 L/min for most MIG work. Too high and you introduce turbulence which pulls atmosphere into the weld pool.
  • Windy or outdoor — push to 20+ L/min and consider a wind break. Once wind exceeds 8 km/h, gas shielding gets compromised; either move indoors or switch to flux-core.
  • TIG — 10–15 L/min is enough. Higher flow doesn’t help and wastes gas.

Cylinder-size rules of thumb

Use caseRecommended size
Occasional MIG, single welderE-size
Full-time single welderG-size
Two or more welders dailyMultiple G-size cylinders
Portable site rigsD or C-size
High-volume TIG shopHigh-volume argon supply setup

Draw rate matters more than absolute gas volume. If you’re emptying a G every day, it’s worth reviewing a higher-volume supply setup.

Cylinder-size rules of thumb

MIG and flux-core dominate the volume in most fabrication shops because the travel speed is high and training time is low. TIG is slower but produces the cleanest bead profile, which is why it rules in stainless food-grade work, aerospace, and the kind of visible welds that never get ground back.

The gas decision follows the process, not the other way around. If you’re setting up a new rig, decide the process first, then pick the gas, then size the cylinder.

Cylinder-size rules of thumb

Solid wire (ER70S-6 for mild steel) works well with the standard Ar/CO₂ mixes. Metal-cored wires often push better with slightly higher-argon mixes (like 85/15 or 90/10 Ar/CO₂) to give a smoother arc. Stainless wires (ER308LSi and similar) want tri-mix or Ar/O₂, not CO₂-heavy mixes — too much CO₂ carbonises the weld pool and drops corrosion resistance.

Aluminium wire (ER5356, ER4043) wants pure argon below 6mm, and argon/helium blends above. Helium adds heat input, which matters on thick aluminium because aluminium conducts heat away from the weld faster than steel does.

Always read your wire manufacturer’s gas recommendation on the spool. They’ve usually tested it.

Call us and we’ll size the cylinder to your actual draw rate — hire cost isn’t worth over-sizing, and under-sizing means mid-shift swaps.

Order from us

Related

Gas

Industrial Oxygen

Industrial oxygen for oxy-fuel cutting, brazing, heating and metal fabrication.

Gas

Argon

Straight argon for TIG welding, aluminium work, purging and plasma-assist jobs.

Application

Welding & Fabrication

Shielding, cutting, laser gas and welding gases for MIG, TIG, oxy-fuel and fabrication work.

Gas supply. No runaround.

Tell us what you need. We’ll confirm timing, paperwork and the next step.
Most metro orders placed by 2pm arrive next business day. Other zones run on schedule.
Puregas Australia Gas Supplier
Gas supply. Done right.
Australian-owned gas supply for industrial, welding, hospitality, food-grade, LPG and specialist supply needs.

Clear terms. Straight pricing. Specialist gas advice. One number.
Welding, hospitality and selected cylinder gases available nationally through 200+ dealer locations. Specialist supply confirmed by location.
One number · Orders · Trade accounts · Technical & SDS · Wholesale.
Melbourne operations
Victoria, Australia
Mon–Fri 8–4:30